Suitable for retrofit! Aisin GHP also corresponds to the expanding demand of retrofit.
Retrofit All E series are applicable for retrofit. Since it is possible to reuse the existing pipeline, the installation cost can be reduced. Replacement of existing equipment with high efficiency models would be a great help in reducing the running costs.

Reusing the existing pipeline can significantly reduce the installation time and cost.

Units using following 3 types*2 of refrigeration oil can be linked for retrofit applications. Existing EHP pipelines can be also reused!

A retrofit model is equipped with a built-in filter kit which enables to reuse the existing pipeline without the need for flushing the pipe*1.


(*1)
Flushing may be necessary depending on the model or the condition in which the product is installed.
(*2)
For the possibility of combinations other than the above, please contact the dealer whom you purchased the product or contact AISIN via inquiry form.
*
It may be possible to reuse the existing pipeline in which the types of refrigerant other than those listed above flows. Please contact the dealer whom you purchased the product or contact AISIN via inquiry form for more details.
The existing pipeline may not be reused in some cases. Please contact the dealer whom you purchased the product or contact AISIN via inquiry form for more details.
For specific instructions about retrofitting an existing air-conditioner, please contact the dealer whom you purchased the product or contact AISIN via inquiry form for more details.
Existing pipelines can be reused!

Combined installation flexibly fits a variety of retrofit

Retrofit example 1

A series P560 X 5 units
Floor area:23.22m2
Weight:970kg X 5 units =4850kg
Retrofit example
retrofit
E1 series P710 X 4 units, combined installation
Floor area:15.37m2
Weight:765kg X 4 units = 3060kg
Approx. 34% Space saving
Combined installation flexibly fits a variety of retrofit applications

Retrofit example 2

P560 X 2 units + P280 X 1 unit
Floor area:12.89m2
Weight:970kg X 2 units + 490kg X 1 unit = 2430kg
Retrofit example
retrofit
E1 series P710 X 2 units, combined installation
Floor area:8.05m2
Weight:765kg X 2 units = 1530kg
Approx.34% Space saving
Combined installation flexibly fits a variety of retrofit applications

Significant reduction in fuel gas consumption

Improvements in energy efficiency could significantly reduce fuel gas consumption. It also achieves lower running costs and CO2 emissions reductions.

For more details, 'Fuel gas consumption'

Reducing floor space requirements for maintenance service can save the installation space

By optimizing the major components layout, the required working space in front of the unit reduced from 1,000mm to 700mm. It becomes possible to install the unit into the space where there is not enough space available in front of the unit. Moreover, because the exhaust drain filter box is relocated to the front side, all maintenance work can be performed from the front side.

For more details, 'Reducing floor space requirements for maintenance service'

Extended maximum pipe length from 40m up to 60m. (after the first branch)

* Length differences between the first branch joint and the most distant indoor unit and between the first branch joint and the closest indoor unit must not exceed 40m.

The maximum pipe length from the first branch joint to the most distant indoor unit is extended from 40m to 60m and that achieves extensive design freedom. Because the number of connectable indoor units per one outdoor unit increases, air-conditioning design layout, which is not possible to plan with the D1 series, becomes possible with the E1 series (but not for all cases).

For more details, 'Extended pipe length up to 60m'